Review




Structured Review

Biosense Webster variable loop circular catheter vlcc
Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in <t>VLCC.</t> The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+circular+catheter+vlcc/catheter+circular+loop+variable/pmc12866922-107-1-11
Average 86 stars, based on 1 article reviews
variable loop circular catheter vlcc - by Bioz Stars, 2026-09
86/100 stars

Images

1) Product Images from "Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter"

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter

Journal: Europace

doi: 10.1093/europace/euag005

Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Figure Legend Snippet: Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Techniques Used: Solvent, Magnetic Resonance Imaging

Related Articles

Solvent:

Article Title: Low acute complication rates with a variable loop pulsed field ablation catheter: Early real-world experience from the REAL-AF registry.
Article Snippet: With the recent relaunch of the Varipulse (Biosense Webster) variable loop circular catheter (VLCC), new instructions for use were issued, including regulatory approval for a 30 mL/min irrigation rate during ablation to mitigate electrode heating and potentially improve procedural safety.1 Although pivotal trials have demonstrated favorable outcomes with the VLCC, real-world data across diverse operators and centers are needed to validate these results.2,3 We report acute safety outcomes from the ongoing REALAF registry, focusing on procedures performed with the VLCC across participating sites in the United States.

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter
Article Snippet: A variable-loop circular catheter (VLCC) with an adjustable irrigation system (VARIPULSE, Biosense Webster, Irvine, CA, USA) and a three-dimensional electro-anatomical system (Carto 3, Biosense Webster, Irvine, CA, USA) was used throughout the experiments.

Magnetic Resonance Imaging:

Article Title: Low acute complication rates with a variable loop pulsed field ablation catheter: Early real-world experience from the REAL-AF registry.
Article Snippet: With the recent relaunch of the Varipulse (Biosense Webster) variable loop circular catheter (VLCC), new instructions for use were issued, including regulatory approval for a 30 mL/min irrigation rate during ablation to mitigate electrode heating and potentially improve procedural safety.1 Although pivotal trials have demonstrated favorable outcomes with the VLCC, real-world data across diverse operators and centers are needed to validate these results.2,3 We report acute safety outcomes from the ongoing REALAF registry, focusing on procedures performed with the VLCC across participating sites in the United States.

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter
Article Snippet: A variable-loop circular catheter (VLCC) with an adjustable irrigation system (VARIPULSE, Biosense Webster, Irvine, CA, USA) and a three-dimensional electro-anatomical system (Carto 3, Biosense Webster, Irvine, CA, USA) was used throughout the experiments.



Similar Products

86
Biosense Webster variable loop circular catheter vlcc
Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in <t>VLCC.</t> The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+circular+catheter+vlcc/catheter+circular+loop+variable/pmc12866922-107-1-11
Average 86 stars, based on 1 article reviews
variable loop circular catheter vlcc - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Biosense Webster open-irrigated variable-loop circular catheter (vlcc)
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Open Irrigated Variable Loop Circular Catheter (Vlcc), supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+circular+catheter+vlcc/open+irrigated+variable+loop+circular+catheter++vlcc+/pmc12127796-18-5-30
Average 90 stars, based on 1 article reviews
open-irrigated variable-loop circular catheter (vlcc) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Biosense Webster variable-loop circular catheter vlcc varipulse
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Variable Loop Circular Catheter Vlcc Varipulse, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+circular+catheter+vlcc/varipulse+catheter/pmc12127796-7-9-14
Average 90 stars, based on 1 article reviews
variable-loop circular catheter vlcc varipulse - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Biosense Webster varipulsetm variable-loop circular catheter vlcc
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Varipulsetm Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/variable+loop+circular+catheter+vlcc/varipulse+catheter/pm39004800-21-33-39
Average 90 stars, based on 1 article reviews
varipulsetm variable-loop circular catheter vlcc - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Journal: Europace

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter

doi: 10.1093/europace/euag005

Figure Lengend Snippet: Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Article Snippet: A variable-loop circular catheter (VLCC) with an adjustable irrigation system (VARIPULSE, Biosense Webster, Irvine, CA, USA) and a three-dimensional electro-anatomical system (Carto 3, Biosense Webster, Irvine, CA, USA) was used throughout the experiments.

Techniques: Solvent, Magnetic Resonance Imaging

Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the VLCC influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.

Journal: European Heart Journal. Case Reports

Article Title: Voltage threshold adjustments for a novel pulsed-field ablation catheter with integrated mapping capabilities: lessons from a case series

doi: 10.1093/ehjcr/ytaf231

Figure Lengend Snippet: Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the VLCC influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.

Article Snippet: It consists of an open-irrigated variable-loop circular catheter (VLCC) with 10 electrodes (electrode length 3 mm, inter-electrode spacing 7 mm center-to-center) and is capable of both mapping and PFA (Varipulse, Biosense Webster, Irvine, CA, USA).

Techniques: Comparison

The left figure in each panel shows the high-density bipolar voltage map acquired with a dedicated mapping catheter (Octaray) and displayed with the standard voltage thresholds. The right figures show the maps acquired with the novel variable-loop circular catheter (VLCC, Varipulse) displayed with different bipolar voltage thresholds. Patient #1 underwent an index PVI with four isolated veins after PFA. Patient #2 underwent a redo PVI with a reconnected left lower pulmonary vein at the beginning of the procedure. Patient #3 shows wide antral PVI and scar on the posterior wall during a redo case. Patient #4 presented with an anterior scar. This map was acquired during a roof-dependent flutter, the tachycardia mechanism of which was also correctly identified by the VLCC. PFA, pulsed-field ablation; PVI, pulmonary vein isolation.

Journal: European Heart Journal. Case Reports

Article Title: Voltage threshold adjustments for a novel pulsed-field ablation catheter with integrated mapping capabilities: lessons from a case series

doi: 10.1093/ehjcr/ytaf231

Figure Lengend Snippet: The left figure in each panel shows the high-density bipolar voltage map acquired with a dedicated mapping catheter (Octaray) and displayed with the standard voltage thresholds. The right figures show the maps acquired with the novel variable-loop circular catheter (VLCC, Varipulse) displayed with different bipolar voltage thresholds. Patient #1 underwent an index PVI with four isolated veins after PFA. Patient #2 underwent a redo PVI with a reconnected left lower pulmonary vein at the beginning of the procedure. Patient #3 shows wide antral PVI and scar on the posterior wall during a redo case. Patient #4 presented with an anterior scar. This map was acquired during a roof-dependent flutter, the tachycardia mechanism of which was also correctly identified by the VLCC. PFA, pulsed-field ablation; PVI, pulmonary vein isolation.

Article Snippet: It consists of an open-irrigated variable-loop circular catheter (VLCC) with 10 electrodes (electrode length 3 mm, inter-electrode spacing 7 mm center-to-center) and is capable of both mapping and PFA (Varipulse, Biosense Webster, Irvine, CA, USA).

Techniques: Isolation